Tensile modulus, low thickness
10000
MPa
ISO 527-1/-2
Tens. Mod. (Thickness tested)
1
mm
ISO 527-1/-2
Stress at break, at low thickness
210
MPa
ISO 527-1/-2
Stress at break (Thickness tested)
1
mm
ISO 527-1/-2
Strain at break, at low thickness
3.8
%
ISO 527-1/-2
Strain at break (Thickness tested)
1
mm
ISO 527-1/-2
Flexural strength (120°C)
160
MPa
ISO 178
Flexural strength (160°C)
130
MPa
ISO 178
Charpy impact strength (+23°C)
80
kJ/m²
ISO 179/1eU
Charpy impact strength (-30°C)
65
kJ/m²
ISO 179/1eU
Charpy notched impact strength (+23°C)
12
kJ/m²
ISO 179/1eA
Charpy notched impact strength (-30°C)
11
kJ/m²
ISO 179/1eA
Izod notched impact strength (+23°C)
12
kJ/m²
ISO 180/1A
Izod notched impact strength (-40°C)
11
kJ/m²
ISO 180/1A
Weldline strength at thickness 1
100
MPa
ISO 527-1/-2
Weldline strain at thickness 1
1.5
%
ISO 527-1/-2