Tensile modulus, low thickness
10800
MPa
ISO 527-1/-2
Tens. Mod. (Thickness tested)
1
mm
ISO 527-1/-2
Stress at break, at low thickness
200
MPa
ISO 527-1/-2
Stress at break (Thickness tested)
1
mm
ISO 527-1/-2
Strain at break, at low thickness
2.4
%
ISO 527-1/-2
Strain at break (Thickness tested)
1
mm
ISO 527-1/-2
Flexural strength (120°C)
180
MPa
ISO 178
Flexural strength (160°C)
120
MPa
ISO 178
Flexural strength (200°C)
100
MPa
ISO 178
Charpy impact strength (+23°C)
60
kJ/m²
ISO 179/1eU
Charpy notched impact strength (+23°C)
10
kJ/m²
ISO 179/1eA
Weldline strength at thickness 1
55
MPa
ISO 527-1/-2
Weldline strain at thickness 1
0.6
%
ISO 527-1/-2
Weldline strength at thickness 2
100
MPa
ISO 527-1/-2
Weldline strain at thickness 2
1.1
%
ISO 527-1/-2